GPRS GPS SMS Data Logger Wireless GSM Remote Controller 4 Analog Input 1

Digital Relay Output Temperature Alarm System S262

 

GSM S26X

The King Pigeon S262 S263 Data Logger inbuilt industrial Quad-band GPRS Engine,and GPS module optional. 4 channel
Analog inputs (0-20mA,4-20mA,0-5V) support Ultra-Low/Low/High/Ultra-High limit alarm monitoring.

One digital relay output with NC/NO contacts controlled by alarm event,SMS command or Rejected Caller-ID(charge free).

With Internal memory, S262 S263 save historical data half a year for inquiry & download by PC software via USB cable or KingCenterCMS-02 Remote Monitoring System via GPRS TCP/IP, and tracking the real time GPS location with optional GPS module.Daily report, schedule upload, event upload via GPRS to remote monitoring center (TCP/IP) or by SMS to users mobile phone directly.

S262/S263 used for field monitoring in worldwide, we offer GPRS protocol for clients to build their own monitoring software/applications.

S26x Solutions banner 650 262

234

Typical Project

A. Wide Range Temperature Alarm and Record

Save temperature data(-200~200°C,-70~500°C) on local unit,get alert SMS and phone call when temperature exceed

pre-settingvalue, download the historical data by USB (PC Programming Software) every few months or half a year.

 

Suitable for: Manufacture,Machine factory,Cold room, Medicine center.

Steps

1: Install S262 on site

2: Setting alert value and record interval time

3: Download historical data to PC by USB

What you need

S262 Standard Kit + SIM Card + TMI500

PC Progrramming Software

Mobile Phone number for receiving alert

Computer with WinXP or Win7/8 OS

B. Real Time Unman Station Monitoring

Install the S262 and detectors on the station,record and report real time data to KingCenter CMS-02 via GPRS TCP/IP remotely,

as well as send alert SMS and making phone call when temperature/current/voltage/humidity/water level data exceed pre-setting value.

Suitable for: 

Server room,Medicine center, Weather station,Agriculture,Pump station,Oil supplier,Water supplier,Fuel pipe,BTS station,etc.

Steps

1: Install S262 and detectors

2: Setting alert value and record interval time & GPRS parameters

3. Remote monitoring real timedata

4: Download historical data

What you need

S262 Standard Kit + SIM Card + WLI100 + Current/Voltage transducer + TMI300

PC Progrramming Software

Mobile Phone number for receiving alert

KingCenter CMS-02 System

DNS/Server IP address and Port

Computer with WinXP or Win7/8 OS

 

C. Real Time Fuel Level Monitoring and Record with GPS Tracking

Install the S262 on vehicle,save fuel level and temperature data on local unit,get alert SMS and phone call when temperature or

fuel level(in case of gasoline theft) exceed pre-setting value, get GPS tracking info on Google Map, Remote monitoring real time

values and download historical data anytime anywhere by KingCenter CMS-02 System via GPRS TCP/IP.

Suitable for: Refrigerated transport,Cold truck,Seafood transport,Logistics Management,Construction vehicle,etc.

Steps

1: Install S262 and detectors on vehicles

2: Setting alert value and record interval time & GPRS/UMTS parameters

3. Remote monitoring real time data and GPS location

4: Download historical data remotely

What you need

S262 +GPS Standard Kit + SIM Card + TMI500 + WLI100

PC Progrramming Software

Mobile Phone number for receiving alert

KingCenter CMS-02 System

DNS or Server IP address and Port

Computer with WinXP or Win7/8 OS

5

feature

1.  GSM Quad-Band,distribute worldwide applications available

2.  4 channel analog input: 0-20mA, 4-20mA, 0-5V

3.  SMS command or PC Software programming

4.  User-programmable alarm thresholds (Ultra-Low/Low/High/Ultra-High)

5.  6 numbers for receiving input alert and relay control

6.  Relay control programmable when alarm thresholds exceed

7.  Relay control by Caller-ID with free of charge, SMS, GPRS (*work with KingCenter CMS-02)

8.  Recording data on internal memory:

Min interval: per 5 mins, can save data on unit more than 6 months

Max interval: per 255 mins,can save data on unit more than 10 years

9.  Historical data download to PC ( .csv format) via USB

10.  Historical data query and download remotly by GPRS (*work with KingCenter CMS-02)

11.  Supports 2 Server(Master and Slave) via GPRS

12.  Daily report, schedule upload, event upload programmable

13.  AC/DC Power status monitoring, AC ON/OFF alert by SMS

14.  Rechargeable Backup Battery inside (Approx. 8 hours standby)

15.  IP67 Environmental protection enclosure(S263)

 16.  GPS tracking module optional

 

Specifications

1.  GSM Frequency: Quad-band,850/900/1800/1900MHz

2.  Input Channel: 4 Analog, 0-20mA, 4-20mA, 0-5V

3.  Output:  1 Relay, NC/NO contacts, 7A/125V AC, 5A/250VAC,20A/14VDC

4.  Power Supply :  9~24VDC 2A

5.  Power Consumption:  12V input Max.50mA/Average 25mA

6.  SIM Card Supporting:  3V SIM Card

7.  GSM Antenna:  50 ohm SMA Antenna interface

8.  Backup Battery:  3.7V/1200mAH

9.  Relative Humidity:  90%(condensation free)

10.  Installation:  35mm DIN Rail (S262)

IP67 Enclosure (S263)

11.  Connecting Wires:  2.5mm

12.  Exterior Dimensions:  145*90*41mm (S262)

180*140*60mm (S263)

 

S26x Series PC Programming Tool (Windows XP and Windows 7/8 OS) Functions:

1.  Authorized users setting

2.  GPRS Parameters setting

3.  Server IP and Port setting

4.  Ultra-Low/Low/High/Ultra-High alarm thresholds

5.  Query current values

6.  Data recording interval

7.  Historical data inquiry and export( .csv format)

8.  SMS Daily report interval

9.  GPRS data upload interval

10.  Relay action setting

11.  Relay test

12.  Date & Time adjustment

 13.  GPRS data transceiving debug

 

S260 GPRS GPS 1.s262 temperature logger alarm sms receiver

2.S262 GPRS GPS temperature logger setting

3.S262 GPRS GPS temperature logger setting 2

4.S262 GPRS GPS temperature logger Historical data

 Packing list:

Main unit 2G*1

100~240VAC/12VDC 2A Power adaptor *1

GSM Antenna *1

User Manual & PC Software CD *1

Size: 235 * 225 * 65mm

Gross Weight: 0.75KG

 6

Optional accessories:

-200~500 Temperature transducer with anticorrosion packing

Fuel/Water level transducer

 Current/Voltage transducer